Skip to product information
1 of 1

Marine Education Textbooks

S-400 Fuel Transfer Procedures

S-400 Fuel Transfer Procedures

Regular price $8.38 USD
Regular price Sale price $8.38 USD
Sale Sold out
Shipping calculated at checkout.

FUEL TRANSFER PROCEDURES: The following

procedures should be followed for vessel fuel transfers:

. A minimum of two qualified people is mandatory for the

following fuel transfers; diesel oil, lube oil and bilge/slop oil.

. The captain on watch is responsible for the personnel

transferring fuel and the amount being transferred.

. Perform pre-fueling inspection in accordance with the Coast

Guard Declaration of Inspection DOI and ensure that all

requirements are met prior to commencing the fuel transfer.

. Gauge all fuel tanks and ensure an accurate starting inventory.

. Set valves for tanks to be filled.

. Ensure that the vents for all tanks to be pumped out or loaded

are clear and fitted with flame screens.

. Ensure that drip containers are in place at all hose connections

and vents.

. Monitor the liquid level in the tanks constantly during

loading. Do not fill tanks beyond 90% of total tank capacity.

. After loading or discharge is complete and the pumps are

secured, secure all valves.

. Disconnect hoses and refit hose caps or blind flanges.

. Gauge all fuel tanks to obtain an accurate ending inventory.

. Log the amount of fuel received or transferred.

View full details